Curtain Wall Design Calculations
Curtain wall this wall is designed to be cast onto the top of the abutment after the deck has been built.
Curtain wall design calculations. Curtain wall design can be a good business or it can be terrible. Wind load computation procedures are divided into two sections namely. Establish the required condensation resistance factor crf based on anticipated interior humidity and local climate data and select a curtain wall with an appropriate crf. Review of curtain walls focusing on design problems and solutions karol kazmierczak 1 abstract this paper presents curtain walls their fundamental classification challenges associated with their design and construction.
Calculation procedure for design wind load on curtain walls the design wind load can be found according to asce 7 10 minimum design loads for buildings and other structures. A balanced holistic approach to the curtain wall construction is emphasized. Facade curtain wall structural analysis structural calculation. Structural calculation curtain wall page 1 2.
Often decision is based on contractor s cost analysis. It seems that most of these calculations use the 2005 aluminum design manual which as far as i can tell doesn t require j torsional constant or c w torsional warping constant when finding allowable stresses for basically. Aama s curtain wall design guide provides guidance on window selection for condensation resistance. Wind loads for main wind force resisting systems and wind loads on components and cladding.
Designers should be aware that the crf is a weighted average number for a. Piece built and glazed on site 3. Pre built with glazing in a shop. Analysis and design of curtain wall systems for high rise buildings a dissertation submitted by wong wan sie winxie in fulfillment of the requirements of courses eng4111 and 4112 research project.
Structural calculation for aluminium mullion 19 chapter 5. Selection may be specified. Basic curtain wall assemblies 1. Erected on site 4.
Structural calculation for aluminium transom 33 chapter 6 design of brackets 48 chapter 7. Introduction 3 chapter 2. Loading will be applied from the backfill surcharge and braking loads on top of the wall. In this paper design concerns of the unitized curtain wall system are.
Hb braking load to bs 5400 clause 6 10 25 45units 4 10kn on 2 axles 225kn per axle. Structural calculation curtain wall sample design 1. Structural analysis on glass 15 chapter 4. Two basic ways to assemble curtain wall systems 2.
American australian british standards etc.